  <item>
    <title>Element D5038 - Security Systems - ODG121312</title>
    <description>
      Archived design guideline Element.
      - Please direct questions and comments to Laura Oswalt at 713-794-5733.
    </description>
    <link></link>
    <guid isPermaLink="false">D5038 ODG121312</guid>
    <pubDate>Thu, 13 Dec 2012 08:40:12 CDT</pubDate>
  </item> 
  
  <item>
    <title>Element D5038 - Security Systems - ODG052412</title>
    <description>
      2.01 C, D: Added reference to CPTED and overview of security system; 2.04 Video Recording:  Added B-F; 2.05 C: Added Hub Room requirements; 2.12: Added Site Security section; 2.13: Added Main Lobby section; 2.14 B: Added security for individual floors; 2.18: Added Equipment Room section; 2.19: Added Stairwells section; 2.24: Added Staff Lockers / Showers section; 2.25: Added Working Mothers Rooms section; 2.26: Added Shell Space section; 2.07: referenced other areas for security; 4.06:  Referenced hazardous materials storage. 5.02: Added Security Equipment Schedules section; 5.03: Added Access Control Hardware on Doors in Means of Egress requirements.
      - Please direct questions and comments to Monsie Mintz at 713-563-7786.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/odg_archives/odg_r02/D5038-M.pdf</link>
    <guid isPermaLink="false">D5038 ODG052412</guid>
    <pubDate>Thu, 24 May 2012 08:45:10 CDT</pubDate>
  </item>

  <item>
    <title>Element Z201001 - Design Phase Deliverables - ODG052412</title>
    <description>
      Updated security system deliverables with door schedule requirements for security interface.
      Please direct Question or Comments to Monsie Mintz at 713-563-7786.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/odg_archives/odg_r05/Z201001-M.pdf</link>
    <guid isPermaLink="false">Z201001 ODG052412</guid>
    <pubDate>Thu, 24 May 2012 08:45:09 CDT</pubDate>
  </item>
  
 <!-- 
 
  <item>
    <title>CSI Division 28 - Fire Alarm and Smoke Detector System, Section 28 30 00 - MS060211</title>
    <description>
      Various editorial changes throughout document.
      Please direct questions and comments to Bryan Galloy at 713-792-1284.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/specs/div28/28%2030%2000.doc</link>
    <guid isPermaLink="false">28 30 00 MS060211</guid>
    <pubDate>Thu, 02 Jun 2011 08:30:50 CDT</pubDate>
  </item>  
  
  <item>
    <title>CSI Division 28 - Fire Alarm and Smoke Detector System, Section 28 30 00 - MS052411</title>
    <description>
      Clarified RFI process 1.02 Summary; clarification on skirt enclosures Section 2.07 for speakers, strobe lights, audible/visible devices; Section 2.07 and 2.08: clarification on relays, electronic control relays, and electronic control modules regarding LED indictor lights. 1.02 B, C; 2.07 B5, C8, and D9; 2.07E; 2.08E and G10; 3.04 A10.
      Please direct questions and comments to Bryan Galloy at 713-792-1284.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/specs/div28/28%2030%2000.doc</link>
    <guid isPermaLink="false">28 30 00 MS052411</guid>
    <pubDate>Tue, 24 May 2011 08:20:40 CDT</pubDate>
  </item>

  <item>
    <title>CSI Division 28 - Electronic Safety and Security, Section 28 05 00 - MS033111</title>
    <description>
      Archived section to allow consultant to create specifications for individual projects.
      Please direct questions and comments to Monsie Mintz at 713-563-7786.
    </description>
    <guid isPermaLink="false">28 05 00 MS033111</guid>
    <pubDate>Thu, 31 Mar 2011 08:42:01 CDT</pubDate>
  </item>  
  
  <item>
    <title>CSI Division 28 - Fire Alarm and Smoke Detector System, Section 28 30 00 - MS030311</title>
    <description>
      Incorporated major revisions throughout document. - Please direct questions and comments to Bryan Galloy at 713-792-1284.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/specs/div28/28%2030%2000.doc</link>
    <guid isPermaLink="false">28 30 00 MS030311</guid>
    <pubDate>Thu, 03 Mar 2011 08:35:11 CDT</pubDate>
  </item>
    
  <item>
    <title>Element D5038 - Security Systems - ODG070810</title>
    <description>
      Revised 2.07 B Exterior Lighting; Added Part 4 Design Criteria for Research Areas. Please direct Question or Comments to Raymond Gerwitz at 713-563-3080.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/odg_archives/odg_r01/D5038-M.pdf</link>
    <guid isPermaLink="false">D5038 ODG070810</guid>
    <pubDate>Thu, 08 Jul 2010 08:44:12 CDT</pubDate>
  </item>
  
  <item>
    <title>CSI Division 28 - Fire Alarm and Smoke Detector System, Section 28 30 00 - MS021110</title>
    <description>
      Clarified that &quot;EH&amp;S of MDACC is the local code Authority Having Jurisdiction for fire alarm and smoke detection systems equipment, materials, installation and applicable Code interpretations.&quot; Clarified the responsibility of the fire alarm contract that &quot;The Contractor shall not make changes to locations indicated on original Drawings.  All device drawing location changes, additions or deletions shall be made on final Construction Documents sealed by an licensed fire protection approved engineer or licensed fire alarm planner representing the fire alarm systems Contractor, and approved by the Owner.&quot;	1.02 B. and 1.02 D. - Please direct questions and comments to Bryan Galloy at 713-792-1284.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/specs/div28/28%2030%2000.doc</link>
    <guid isPermaLink="false">28 30 00 MS021110</guid>
    <pubDate>Thu, 11 Feb 2010 08:21:19 CDT</pubDate>
  </item>

  <item>
    <title>Element Z2055 - U.T. Police Department Crime Prevention Guidelines - ODG122209</title>
    <description>
      Deleted content and provided Owner’s contact information to allow evaluation and revision of Element.
      Please direct Questions and Comments to David Spain at 713-792-8685.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/odg_archives/odg_r02/Z2055-M.pdf</link>
    <guid isPermaLink="false">Z2055 ODG122209</guid>
    <pubDate>Tue, 22 Dec 2009 08:08:30 CDT</pubDate>
  </item>
  
  <item>
    <title>CSI Division 28 - Fire Alarm and Smoke Detector System, Section 28 30 00 - MS120109</title>
    <description>
      Changed referenced edition of the International Building Code from 2006 to 2009 in Paragraph 1.04 C. 4. - Please direct questions and comments to Bryan Galloy at 713-792-1284.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/specs/div28/28%2030%2000.doc</link>
    <guid isPermaLink="false">28 30 00 MS120109</guid>
    <pubDate>Tue, 01 Dec 2009 08:06:10 CDT</pubDate>
  </item>

  <item>
    <title>Element D5038 - Security Systems - ODG030210</title>
    <description>
      Initial Adoption of Element.
      Please direct Question or Comments to Clifford Smith at 713-563-7786.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/odg_archives/odg_r00/D5038-M.pdf</link>
    <guid isPermaLink="false">D5038 ODG030210</guid>
    <pubDate>Tue, 02 Mar 2010 08:10:14 CDT</pubDate>
  </item>
  
  <item>
    <title>Element G2040 - Site Development - ODG030210</title>
    <description>
      2.01, Note J:  updated requirements for bicycle parking and racks.
      Please direct Question or Comments to Clifford Smith at 713-563-7786.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/odg_archives/odg_r01/G2040-M.pdf</link>
    <guid isPermaLink="false">G2040 ODG030210</guid>
    <pubDate>Tue, 02 Mar 2010 08:10:12 CDT</pubDate>
  </item>

  <item>
    <title>Element G2050 - Landscaping - ODG030210</title>
    <description>
      Added Note I, Section 2.01 on landscaping for security.
      Please direct Question or Comments to Clifford Smith at 713-563-7786.
    </description>
    <link>http://www2.mdanderson.org/depts/cpm/standards/odg_archives/odg_r01/G2050-M.pdf</link>
    <guid isPermaLink="false">G2050 ODG030210</guid>
    <pubDate>Tue, 02 Mar 2010 08:10:10 CDT</pubDate>
  </item>
  
<item>
<title>CSI Division 28 - Fire Alarm and Smoke Detector System, Section 28 30 00 - MS060909</title>
<description>Added requirement that all exposed fire alarm system wiring is readily identifiable by red color. Paragraph 2.01 C. 2.
 Please direct questions or comments to Bryan Galloy at 713-792-1284.</description>
<link>http://www2.mdanderson.org/depts/cpm/standards/specs/div28/28%2030%2000.doc</link>
<guid isPermaLink="false">28 30 00 MS060909</guid>
<pubDate>Tue, 09 Jun 2009 07:20:10 CDT</pubDate>
</item>

<item>
<title>CSI Division 28 - Fire Alarm and Smoke Detector System, Section 28 30 00 - MS070308</title>
<description>General revisions to remove proprietary product language and general specification update.
 Please direct questions or comments to Bryan Galloy at 713-792-1284.</description>
<link>http://www2.mdanderson.org/depts/cpm/standards/specs.htm#div28</link>
<guid isPermaLink="false">28 30 00 MS070308</guid>
<pubDate>Thu, 03 Jul 2008 10:23:14 CDT</pubDate>
</item>

<item>
<title>Element D - Fire Alarm, Communications and Security - ODG070308</title>
<description>Deleted criteria that are part of specification section 28 30 00.
 Please direct questions or comments to Bryan Galloy at 713-792-1284.</description>
<link>http://www2.mdanderson.org/depts/cpm/standards/Guides/D5030-M.pdf</link>
<guid isPermaLink="false">D5030 ODG070308</guid>
<pubDate>Thu, 03 Jul 2008 10:23:11 CDT</pubDate>
</item>

<item>
<title>CSI Division 28 - Electronic Safety and Security, Section 28 05 00 - MS032008</title>
<description>Annual Updates. General revisions throughout document.
 Please direct questions or comments to Clifford Smith at 713-563-7786.</description>
<link>http://www2.mdanderson.org/depts/cpm/standards/specs.htm#div28</link>
<guid isPermaLink="false">28 05 00 MS032008</guid>
<pubDate>Thu, 20 Mar 2008 10:15:10 CDT</pubDate>
</item>

<item>
<title>Element Z2055 - Crime Prevention Guidelines - ODG032008</title>
<description>Annual Updates. General revisions throughout document.
 Please direct questions or comments to Clifford Smith at 713-563-7786.</description>
<link>http://www2.mdanderson.org/depts/cpm/standards/Guides/Z2055-M.pdf</link>
<guid isPermaLink="false">Z2055 ODG032008</guid>
<pubDate>Thu, 20 Mar 2008 10:15:09 CDT</pubDate>
</item>
-->
